TestFast
Create
Log in
Roadmap
Feedback
Bugs & Improvements
0
Log in to your TestFast account to give feedback
Log In
Boards
Feature Requests
Bugs & Improvements
Powered by Canny
Bugs & Improvements
Please search first before posting to help others find and vote for your idea!
Details
Showing
Trending
Sort
Trending
Top
New
Filter
Under Review
Planned
In Progress
Complete
posts
Login is case sensitive
The login seems to require your email to be entered exactly as original, including case sensitivity, this varies from the norm, as emails are not usually case sensitive. Minor issue, decent QOL improvement.
4
·
complete
2
Bonding coding
Removing an observation on the bonding section of summary, not the schedule of inspected items, does not auto tick when the detect is removed from the observation list. Observation list also randomly reorganises itself between deleting items
4
·
complete
2
Software bug - Date fields on page 1 & 2 of DEIC
Strange software bug. If a date field is populated and needs to be changed, the first character I type changes to a different digit. In this case "1" changes to "2". So typing in 12/05/2026 changes to 21/05/2026. This happens consistently across all date fields. Thanks.
6
·
complete
2
Set up board layout
Unable to delete number of circuits when creating board to enter a number less than 2 digits long, have to click down arrow 5 times to create a 5 circuit DB
3
·
complete
2
4.13 RCD for fault protection
Auto ticking for domestic on TNS/ TNCS, able to have it so this only ticks as domestic preset if on TT?
4
·
complete
2
Cable size format
Able to change the format to automatically add the decimal? Currently enter "1" in conductor size and CPC auto fills out as 1.0 which is the nicer looking format
2
·
complete
2
Inspection schedule signature
Bulk sign isn't filling signature on that part, or possibly being removed when one of the autofills is applied
2
·
complete
1
Submain trip times
Circuit test at 1×𝐼Δ𝑛 current but 'Not connected to origin' info is 5×𝐼Δ𝑛 current, so isn't sharing trip time across with rest of characteristics, do submains need to be 5x or can that be changed to 1x now and auto pull the timing from primary board?
2
·
complete
1
typo 3187
MCB autofill suggestions says 3187, should be 3871
2
·
complete
1
Mobile DB upload causes the browser to crash
For some reason, only on mobile devices, when you upload the DB picture to scan it, it will freeze or crash the browser. Firefox will freeze, while Chrome will crash.
2
·
complete
1
Powered by Canny